torpedo heater won't ignite
If your kerosene heater refuses to ignite or is hard to ignite, there are several common reasons you might want to look for: The igniter on your heater is defective. Kerosene Heaters Use Only: Kerosene, No. Come to find out the igniter was bad (This was a new electonic type) I replaced it with one of the old model originals igniters and its been working since. When using the Big Buddy Heater with the 20-pound tank, the regulator and control valve can get clogged by residue formed due to the high PSI from the propane tank. The glo-bar is powered and after 45 seconds the main valve opens. Moving the intake filter briefly returns the pressure to 9.0 but it soon falls. Some seem to run forever :). They will be happy to assist you with this issue, but will need a few more details to do so. Reddy PP200 (formerly the HA1000) Hot Surface Ignitor For Most Desa/Reddy Heaters. Buy GENUINE OEM REDDY HEATER PART - IGNITOR HA1000 PP200: Heater Parts - Amazon.com FREE DELIVERY possible on eligible purchases This heater will run on kerosene, #1 and 2 diesel fuel, JP8/Jet A fuel, and #1 and 2 fuel oil. Any leaks shall be re- "interactionStatistic": { If the proper air pressure is registering on the pressure gauge (see heater decal for proper pressure) and the heater sprays fuel, but you still cannot light up your KFA Portable Heater, there may be an issue with one of the following components: 2. So, it was up the hiway to a different place to buy fuel, put that in the heater and---VOILA!! They are cheap. "headline":"kerosene heater won't light", What I do is take top cover off of heater. Reddy heater will not ignite and having fan problems. }, – Check for a hole(s) in the air hose that connects the air pump to the burner nozzle. Tighten the bolts in the steel ring. I bought a used torpedo heater last year. I ran diesel fuel in it and it ran great after I put several new bits & pieces in it. Hi Steven, Lots of good stuff to look at. 00. Also on the reliability, if you burn Kerosene and not heating oil or diesel in them they seem to go for 2-3 winters before needing service. Fast shipping with global options In fact, wherever you need efficient, dependable heat this heater can get the job done. So, it was up the hiway to a different place to buy fuel, put that in the heater and---VOILA!! Learn more about our fabrication services, Tech Tip: Kerosene Forced Air (KFA) Portable Heaters Not Lighting Up. The cloth slows down the air stream so the igniter has a chance to work. I tried: new fuel, cleaned the spark plug ignitor, cleaned the air filters, cleaned the jets in the fuel injector, (2 of them!) The drafter pressure switch is working ok. The vanes in the pump can be replaced if you can't build enough pressure. The one on the left is a plug.Take it out screw in a vacuume gauge.Turn the heater on adjust the screw on the right until the pressure (vacuum) reaches 3 lbs.If you have spark (you should see it by looking through the back end)It sould run. New and used parts available. I would think the problem is either not fuel in the combustion chamber or no spark(ignitor). The Hi limit switch and Flame rollout switch have continuity through them. If your kerosene heater … installed new fuel lines (rubber) made sure the fuel cap hole was open, scratched my head until it was raw---NOTHING!! Good luck Keno If you have two adjustment screws on the back? Fuel line to venturi could be clogging up due to dirt in the tank. If voltage is present on the control board, that means that your igniter is more than likely the issue and you will need to replace it. "width": 200, Let’s say you turn on your heater and nothing happens. cleaned the electric eye, (down below the injector, in a round rubber plug, with wires from it.,. I have an oil fired furnace ordered and it should be here anytime. The direct fired heater won’t light, and the spark plug isn’t creating a spark; The heater is lighting and then quickly burning out; The Direct Fired Heater Won’t Turn On at All. Does it appear to spray any kerosene ? $23.40 $ 23. You'll only hear from us. } I bought a ready heater,the little one 40,000 btu I think.I have been running it every night for about a month and a half,getting up in the night to fuel it. Not necessarily - it might be pumping ok, but it may not be spraying the right pattern. TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. Procom Heating &... | Answered on Nov 04, 2018. I heat a kennel building with it.It burns 6-7 gallons of diesel from dark to daylight. At each try I can smell a little bit gas and then nothing. Does it appear to spray any kerosene ? Space heaters use tungsten filaments and elements for heating. Probably 40 bucks. Rusty Jones I had the same problem with mine! I have a readyheater pro 155.has been completely serviced,filters air fuel,spark plug new and gapped,air psi set to 5.2 psi,checked for air leaks,new hoese air fuel,tested ign ok, new nozzel.will not fire hot (60 deg),fires cold fine(30 deg).will fire with torch held near spark plug and run fine.any ideas? Does it appear to spray any kerosene ? Pump could be worn causing less air pressure. Also on the reliability, if you burn Kerosene and not heating oil or diesel in them they seem to go for 2-3 winters before needing service. I have an oil fired furnace ordered and it should be here anytime. "@id":"http://www.yesterdaystractors.com/cgi-bin/viewit.cgi?bd=toolt&th=128264", Give it a good cleaning. c)All flame, including the pilot light, if any, shall be extin-guished and the heater allowed to cool, prior to fuel-ing. "interactionType": "http://schema.org/CommentAction", On reddy's anyway there is an adjustment for that. It's spraying fuel okay judging by the diesel smell. But I was wondering how long these heaters usually last? Sad as it is, the torpedo heaters of today are "throw away" units. Each unit is available in natural gas, propane, kerosene, or fuel oil depending on the model. I can get a replacement for about $72 plus shipping but I hate to do that and find that's not the problem. It buzzes but won't kick in. b) Only the type of fuel specified on the heater’s data plate shall be used. Yes the inline thermostats are nice. I have an oil fired furnace ordered and it should be here anytime. installed new fuel lines (rubber) made sure the fuel cap hole was open, scratched my head until it was raw---NOTHING!! I have a Master MH-75T-KFA, a 75KBTU heater that looks exactly like the one above (except no display on circuit board) The Master heaters line includes forced air construction heaters, salamader and torpedo heaters, radiant construction heaters, convection construction heaters, and tank top heaters. There's also a safety device that shuts down the unit if it doesn't see a flame in the chamber. I have a Remington 75 Torpedo heater. I just wondered if they are a short lived thing or what. – Replace the air hose or air pump rotor based on the root of the cause. If you have 24VAC to it but not through it, then the limit is tripped or defective. or just min. If it gets dirty, it can cause intermittent lighting. If the air pressure is incorrect it won't siphon the fuel up from the tank properly. If there is no voltage, you will … Thanks all I'm sorry but I don't know what the problem is. I turned it on and it won’t ignite and there’s a green blinking light I don’t know what the problem is? Need Help? The first sign of trouble from an uncompliant HSI-type of Reddy heater is usually when the heater fails to switch on, or when it switches off automatically after five seconds. So, it was up the hiway to a different place to buy fuel, put that in the heater and---VOILA!! This can be avoided by turning off the tank first and allowing the fuel left in the hose to burn up completely, rather than just switching off the heater. When I plug it in the blower starts but the thing doesn't light. }. If it takes longer especially when it's colder, that tends to indicate an air pressure problem or fuel line problem. First thing I'd check is the air filter. I would think the problem is either not fuel in the combustion chamber or no spark(ignitor). 01 Lots of good stuff to look at. John Deere and its logos are the registered trademarks of the John Deere Corporation. did all of that 3 times---nothing! This insures the wick is completely saturated with kerosene and lights properly. I tried: new fuel, cleaned the spark plug ignitor, cleaned the air filters, cleaned the jets in the fuel injector, (2 of them!) I noticed lately that it took longer and longer to light but now doesnt't at all. This change has also gotten rid of all routine maintenance needed on a standard Forced-Air Torpedo Heater. If you do not have correct air pressure it won't draw fuel no matter what else is going on with your heater. You can contact Jeff Riesberg or another member of our service team a 1-800-553-9053. We stock parts for most brands of torpedo heaters. Troubleshooting tips for reddy spark plug type heaters. The air filter to the pump could have gotten dirty causing not enough air pressure to draw the kerosene. They are cheap. Thanks! We developed our SilentDrive Technology to make that idea into the reality. Both units are from Empire Comfort Systems. also if it only ignites for a little bit then shuts off quickly then its the light sensor. }, The fan doesn’t run, the spark plug doesn’t spark, and the flame doesn’t ignite. "logo": { Thought I'd share a tip on torpedo/ready heater. We stock parts for most brands of torpedo heaters. I have a 2 year old Dayton Tubular Gas Fired Propeller Unit Heater, 30K BTU, in my garage that wont start. Air line to venturi could have a small crack. e)At no time shall more than one day’s supply of heater My John Deere AC 115 torpedo heater won't light, and when it does, it doesn't stay lit when it's under 40 degrees. It's then sprayed in a fine mist into the combustion chamber to mix with air. If your kerosene heater won’t light: Make sure your heater is filled with quality K-2 grade kerosene, and that the wick has been soaked for at least an hour before attempting to light it. I have a JD ac 215 for about 2 years very hard to start says E1 tried it yesterday could not get it to start ,took hood off and fan has hard spots turned it by hand (it was unpluged) when turned back on it did finaly started .Today the same thing has not had over 5 gal of kero since new.could it be air pump rotor clearance. Thanks all I have seen a few that are pretty old. It's then sprayed in a fine mist into the combustion chamber to mix with air. "@type": "WebPage", I have a Remington 55 torpedo style heater that recently quit working. Come to find out the igniter was bad (This was a new electonic type) I replaced it with one of the old model originals igniters and its been working since. Getting 119VAC at cord thats plugged into the heater. Amazon's Choice for kerosene heater igniter. The dealer told me it was humidity from being stored outside overnight but the problem only develops after an hour or two of use not when first starting as one might expect if the cause were being outside. "dateModified": "2004-02-10", Now, is this circuit board failure, or should I still be looking at igniter? I noticed lately that it took longer and longer to light but now doesnt't at all. Many 'torpedo' heaters call for kerosene fuel for this reason (kero doesn't gell). "@type":"DiscussionForumPosting", Thanks all. Any leaks shall be repaired prior to returning the heater to service. If you have to run one much, it may be more economical to get one of the inline thermostats. Pump could be worn causing less air pressure. 80,000 BTU Kerosene/Diesel Forced Air Heater with Thermostat makes powerful, instant heat, ideal for construction sites, workshops, garages, warehouses, and barns. Setting up a space heater is not difficult. Most of those heaters work by an electric motor running an air pump that uses the venturi principle to draw kerosene out of the tank and spray a mist toward a spark plug that is constantly sparking. I would think the problem is either not fuel in the combustion chamber or no spark(ignitor). There's also a safety device that shuts down the unit if it doesn't see a flame in the chamber. It is pumping fuel. FREE Shipping. When using the Big Buddy Heater with the 20-pound tank, the regulator and control valve can get clogged by residue formed due to the high PSI from the propane tank. "height": 57 When replacing the air pump rotor, you must set the proper gap at the top of the carbon rotor. If you do not find any holes, remove and inspect the air pump rotor for cracks and damage. Air line to venturi could have a small crack. "text": "I have a Remington 55 torpedo style heater that recently quit working. It's spraying fuel okay judging by the diesel smell. 30,000 - 60,000 BTU Forced Air Propane Portable Heater $ 89 99. I thought when I was getting below 110 out of the connector with the blue wires that it was the problem, but no way to know for sure. "@type": "InteractionCounter", Sorry to be so long winded with such a short question. After setting all summer in storage sometimes the heater won't "fire up" on the first cold day you want to use it. HeatFast HF160G Portable Home, Jobsite, Construction Site Forced Air Liquid Propane Salamander Torpedo Space Heater with Variable Temperature Control, 155,000 BTU, orange 4.6 out of 5 stars 6 $202.01 $ 202 . I just wondered if they are a short lived thing or what. Also on the reliability, if you burn Kerosene and not heating oil or diesel in them they seem to go for 2-3 winters before needing service. I replaced one on my Reddy Heater a few years ago because the electrode was worn. Drafter motor comes on. Some seem to run forever :) Check the fuel filter, then the plug, filter should be on the intake side in the tank. • When used with thermostat, heater … Please give us a call at 1-800-553-9053 and we’d be happy to help. The one on the left is a plug.Take it out screw in a vacuume gauge.Turn the heater on adjust the screw on the right until the pressure (vacuum) reaches 3 lbs.If you have spark (you should see it by looking through the back end)It sould run. Except sore head! Scott Could be several things. Torpedo heater parts and space heater parts, repair and service. We use cookies to give you the best possible experience on our website. Kerosene heater won’t light. On spark heaters check for the same when igniter sparks. On reddy's anyway there is an adjustment for that. You can put a guage on the pump outlet also and see if you have proper pressure. Search Results For "Torpedo Heater" 9 Items. Reddy heater will not ignite and having fan problems. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them. Fuel line to venturi could be clogging up due to dirt in the tank. The voltage will need to be checked within 1 – 3 seconds of turning the heater on/off switch to the on position. It seems the unit runs okay, but after a while the pilot begins to flickers and is eventually sucked out when starting on the next cycle. The voltmeter should read 120 volts AC. If you are trying to light your KFA Portable Heater and you notice little or no air pressure registering on the pressure gauge, there may be an issue with one of the following components: – Check to make sure the air pump filters and fuel filter are clean. "width": 200, I learned a lot about these things but not enough I suppose. If it takes longer especially when it's colder, that tends to indicate an air pressure problem or fuel line problem. If you have to run one much, it may be more economical to get one of the inline thermostats. c) All flame, including the pilot light, if any, shall be ex-tinguished and the heater allowed to cool, prior to fu-eling. installed new fuel lines (rubber) made sure the fuel cap hole was open, scratched my head until it was raw---NOTHING!! The DXH185KT thermostatically controlled forced air kerosene heater burns at 185,000 BTU/HR and can be used with kerosene diesel, fuel oil or JP-8 fuels. You do need to exercise certain precautions when using space heaters. If it gets dirty, it can cause intermittent lighting. Except sore head! I just wondered if they are a short lived thing or what. cleaned the electric eye, (down below the injector, in a round rubber plug, with wires from it.,. Probably cheaper to replace that first. If there is no voltage, you will need to replace the control board. These restrictions can limit the amount of gas released into your pilot, resulting in a lack of ignition. Get free expert DIY tips, handy support, troubleshooting help & repair advice for all Mr. Heater products. did all of that 3 times---nothing! If there is no power to the relays the heater won't operate in any mode. There's also a safety device that shuts down the unit if it doesn't see a flame in the chamber. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them. Propane heaters are reliable and effective ways to keep any area warm. I have no spark, have replaced spark “plug”, that did nothing, and when I remove wires from circuit board to check output to igniter, I get 82VAC. They should be able to help you out. It started and now it runs good. Verify if there is any air leaks from reddy heater. I replaced the control board and it fired right up. Fix no spark issues with this reddy heater. I have seen a few that are pretty old. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V. They're a bugger to get adjusted correctly! It lights with the cover off, but only intermittently when the top is on. I heat a kennel building with it.It burns 6-7 gallons of diesel from dark to daylight. Re: kerosene heater won't light in reply to Doug, 02-10-2004 08:59:56 Could be several things. Probably 40 bucks. I think some of the newer ones have eyes in them that can get covered be soot from burning diesel. The vanes in the pump can be replaced if you can't build enough pressure. "name": "Yesterday's Tractor Co.", But check air pump air pressure first. d)During fueling, all fuel lines and fuel-line connections shall be inspected for leaks. Our line of heaters are available in forced air, convection, and radiant models, and come in kerosene, propane, natural gas, or gas powered options. Probably 40 bucks. Sad as it is, the torpedo heaters of today are "throw away" units. The forced air type of Remington heater extracts kerosene from the fuel tank and delivers it to the nozzle in the burner head. Now I do! 4.6 out of 5 stars 46. Take a closer look at why Mi‑T‑M continues to lead the industry in engineering innovation, manufacturing processes, and customer and technical service support. $27.00 $ 27. The vanes in the pump can be replaced if you can't build enough pressure. When heater starts I can hear some solenoid clicks inside the gas valve and ignition LED is on. Could be several things. If it does not work then you have some fresh fuel for a new heater. The gas that ignites your burner arrives at your pilot through a gas line. Fast global parts shipping. We paid a plumber to run a new line to both. They're a bugger to get adjusted correctly! Blow-dry and replace the filter and see if the issue has been resolved. I had a reddy heater a few years ago, It quit like that. If it can't get the fuel to where the spark is, it won't light. It started and now it runs good. Know how to setup pump pressure, clear fuel source, repair rotors, check faulty thermostat. Hadn't thought of spark plug. "url": "http://www.yesterdaystractors.com/graphics/smllogo.png", The plumber came and hooked everything up but when I went to light the pilots on the two new units, nothing happened. PP200 Ignitor HA1000 HSI Reddy Desa Master Kerosene Heater. If customers have a need for heat, we have a model to fit the need. We have a customer service tech replying to the email listed above. User manuals, Master Heater Operating guides and Service manuals. This type of heater is portable, so it is easy to move from room to room as needed. "image": { Our patented technology creates a 50% reduction in noise and decreases the energy it takes to power the heater. My dyna-pro 120000 rmc-kfa 120t-pro torpedo heater will not stay on. – Reset the outer ring if any locations are less than .004 inch. All you need to do is unpack and plug it in and you are ready to go. First thing I'd check is the air filter. When I plug it in the blower starts but the thing doesn't light. did all of that 3 times---nothing! (two different models) Symptoms: They light and burn, but about midnight are found to be out—perhaps after working about four hours. Dirt could have built up in the pressure relief valve causing a decrease of air pressure. Saved me from unnecessarily replacing the igniter. Check the fuel filter, then the plug, filter should be on the intake side in the tank. This versatile, multi-fuel heater will be reliable no matter where you use it, be it shop, garage, or barn. Why won't my kerosene heater light? We use cookies to give you the best possible experience on our website. Dirt could have built up in the pressure relief valve causing a decrease of air pressure. Not necessarily - it might be pumping ok, but it may not be spraying the right pattern. Yes, you can get parts for them, but the cost of just a few parts will be very close to the price of a brand new unit. If it fires up then you may wanna consider mixing in some kerosene to make the diesel work better and the kerosene last longer. If it only falls to 7.0, it will continue working but poorly. This rugged heater warms spaces up to 2000 sq. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Interested in purchasing or servicing an electric or gas powered pressure washer? If you have two adjustment screws on the back? Disconnect the igniter wires from the control board and check for voltage on the control board. This can be avoided by turning off the tank first and allowing the fuel left in the hose to burn up completely, rather than just switching off the heater. For inquiries regarding, Mr. Heater, Sunrite, and BaseCamp products, please call: Phone 1-800-251-0001 (USA & Canada) or 216-916-3000 Fax 800-321-0552 or 216-916-3012 }, I replaced one on my Reddy Heater a few years ago because the electrode was worn. We just built a new addition and we have 2 new propane heaters that just will not light. RIDGID R8604242B at $149.00. For the Mi-T-M Pressure Washer Certified Technician. If it can't get the fuel to where the spark is, it won't light. Remington kerosene heaters are available in cabinet style, radiant heat, and forced air models. With a included wheel kit and an 13.8 gallon tank you will get a full 10 hours of run time and the ability to heat up to approximately 4625 square feet of space. Oil burner parts sales and service. Igniter glow plug lights up but no gas. Already had two other propane units in the house. Come to find out the igniter was bad (This was a new electonic type) I replaced it with one of the old model originals igniters and its been working since. I think some of the newer ones have eyes in them that can get covered be soot from burning diesel. Pump could be worn causing less air pressure. Check the condition of the spark plug as well. "@type": "ImageObject", Unfortunately, if that’s the case, there isn’t much you can do to fix it. Is it safe to assume that the problem is with the ignitor? The forced air type of Remington heater extracts kerosene from the fuel tank and delivers it to the nozzle in the burner head. If it's plugged or restricted it will affect fuel delivery. I have bled the gas line. ... Raypak pool heater model P-R2669-EP-C won't start. Step 5 Blow compressed air into the outlet end of the fuel nozzle if you suspect a clog, which could occur when the heater fails to ignite or you notice smoke or an odor. Most of those heaters work by an electric motor running an air pump that uses the venturi principle to draw kerosene out of the tank and spray a mist toward a spark plug that is constantly sparking. I cannot get a sears 50,000 btu torpedo heater to ignite,,I am very mechanically inclined so would you like me to give - Answered by a verified HVAC Technician. It started and now it runs good. This Site Might Help You. Kerosene Heater Troubleshooting. One point--don't mess with the two screws on the little black plastic cap at the back of the burner, if it has them. cleaned the electric eye, (down below the injector, in a round rubber plug, with wires from it.,. If it gets dirty, it can cause intermittent lighting. Hadn't thought of spark plug. The unit is a 60K BTU torpedo heater. If this is the first time lighting, make sure the heater is filled with quality 1-K kerosene and the wick has soaked in a full tank of fuel in the lowered position for 60 minutes. NEW. I had a reddy heater a few years ago, It quit like that. Fast global parts shipping. In this case, you might want to quickly check the power cord of your heater and see if it has been plugged in correctly. It buzzes but won't kick in. Scott Check the condition of the spark plug as well. We sell parts for most brands and models. Most of those heaters work by an electric motor running an air pump that uses the venturi principle to draw kerosene out of the tank and spray a mist toward a spark plug that is constantly sparking. ... Cant get my electric kerosene heater to light. • Unplug heater when not in use. Lots of good stuff to look at. Im guessing its the board, but wondering if anyone else has seen this? A kerosene heater can help keep you warm during a power outage. Bauer. One is a fireplace, the other a wall unit. Hadn't thought of spark plug. I'm sorry but I don't know what the problem is. The air filter to the pump could have gotten dirty causing not enough air pressure to draw the kerosene. FREE Shipping. ", 4.6 out of 5 stars 160. You can also find answers to frequently asked questions, maintenance tips, and product manuals in our Support Center. After three unsuccessful attempts to ignite Fenwall diagnostic LED blinks 3 times (ignition lockout). Rusty Jones I think some of the newer ones have eyes in them that can get covered be soot from burning diesel. Most of those heaters work by an electric motor running an air pump that uses the venturi principle to draw kerosene out of the tank and spray a mist toward a spark plug that is constantly sparking. The voltage will need to be checked within 1 – 3 seconds of turning the heater on/off switch to the on position. I've got a 150,000 btu Reddy-Heater that still looks almost new, but was retired to the junk shed several years ago. I figured I'd try and post this here as I saw a previous post with a problem involving their torpedo heater. • Keep children and animals away from heater. "url": "http://www.yesterdaystractors.com/graphics/smllogo.png", Can anyone suggest a solution? If you have two adjustment screws on the back? However, like any machine, they can have issues from time to time. Mi‑T‑M Corporation offers a full range of fabrication and precision machining services. 0 Answers Find parts for procom heater md#ml100tbahr ... Our procom propane heater has just started going out I ignite the pilot the burner comes on & stays on for a few days a couple hrs. I've got a 150,000 btu Reddy-Heater that still looks almost new, but was retired to the junk shed several years ago. RE: I have a remington 150,000 btu kerosene torpedo heater that wont run? I went to light but now doesnt't at all seconds the main valve opens fuel line problem level or... Natural gas, the pilot must be continuously burning or it must whenever... Sites warm when it counts the most -- has some kerosene in it and it great! Can look through the intake side in the tank torpedo heater that wont run combustion or... Procom Heating &... | Answered on Nov 04, 2018 elements for Heating placement the. 'S a $ 20 gamble on the back heater -- has some in! Voltage on the intake filter briefly returns the pressure relief valve causing a decrease of air pressure problem or line... A used torpedo heater that wont start is no power to the pump can be replaced if have... Soon falls look into is the placement of the carbon rotor hose that connects air. Was given to me that it took longer and longer to light the pilots on model! ’ d be happy to help the burner head fabrication and precision machining services down the if... The junk shed several years ago because the electrode was worn be on the pump outlet also see. Lighting up the glo-bar is shut off during the last three seconds of heater. My dyna-pro 120000 rmc-kfa 120t-pro torpedo heater last year get free expert DIY tips, handy Support troubleshooting. Real cold when you try to start the heater the best possible experience on our website looks almost new but. In response a hole ( s ) in the combustion chamber to mix with air s data plate be. That are pretty old in reply to Doug, 02-10-2004 08:59:56 could be clogging up due dirt. Dayton Tubular gas fired Propeller unit heater, 30K BTU, in my garage torpedo heater won't ignite wont run fact, you... 02-10-2004 08:59:56 could be several things power outage looking at igniter garage wont! Spark ( ignitor ) – check for a few years ago, it may be more to. Round rubber plug, with wires from the tank got a 150,000 BTU that... It does n't see a flame in the tank properly 45 seconds the main valve opens just a! Heater on a full range of fabrication and precision machining services in response and having fan.... S 45, 000 BTU Kerosene/Diesel forced air ( KFA ) portable heaters specified on the?. Is real cold when you try to start the heater ’ s data plate shall be repaired prior to the. This problem will correct itself as soon as it is, the other wall... Or storing heater, 30K BTU, in my garage that wont run any area warm wires the. Connects the air pressure outlet also and see if you have proper pressure the pressure 9.0... There 's also a safety device that shuts down the unit if it falls! Little more fuel no matter where you use it, be it shop, garage, or your. Do to fix it you use it, be it shop, garage, or fuel spillage may.... Hello, i purchased the JD ac 215 January 30, 2020 for outdoor use team a.! January 30, 2020 for outdoor use line to venturi could be clogging up due to dirt in the.., handy Support, troubleshooting help & repair advice for all Mr. heater questions, problems, & answers isnt... A used torpedo heater for kerosene fuel for this reason ( kero does see... On your heater and -- -VOILA! heater on a full range of fabrication and precision machining services techs. Filter to the email listed above garage that wont run at the top on... As it is, the pilot wo n't start with cover on 7.0. The inline thermostats went to light but now doesnt't at all to 7.0, it quit like that customer... And we ’ d be happy to assist you with this issue, but it soon falls lived. It, then the plug, filter should be here anytime filter and see you... All Mr. heater products a decrease of air pressure torpedo style heater that wont run problem mine... Call for kerosene fuel for this reason ( kero does n't see a flame in the blower but! With cover on fine mist into the reality.004 inch air gap every turn. Judging by the diesel smell 9 Items the pressure relief valve causing decrease... Steven, you can look through the intake and see the spark plug firing routine maintenance needed torpedo heater won't ignite! Portable heater radiant heat, we have a need for heat, we have a small crack 30! Well for a few that are pretty old manuals in our Support Center a... Damaged over time getting more raw fuel than atomized fuel it will never.... Forum-Wide issues, problems and bugs, and the flame doesn ’ t ignite to daylight soon it... Retired to the nozzle in the meantime, please feel free to give us a call at 1-800-553-9053 the rotor! Top of the inline thermostats a fire may occur unpack and plug it the. It tries to ignite the gas, propane, kerosene, or fuel spillage may.. • when moving or storing heater, keep heater in a round rubber plug, with from... Store Finder ; b ) only the type of heater Download 213 heater... Answered on Nov 04, 2018 carries a large varity of portable heaters not lighting.. Fuel-Line connections shall be used fan doesn ’ t run, the torpedo heaters enough. Ferguson and their logos are registered trademarks of CNH Global N.V Global options View recent heater. Purchased the JD ac 215 January 30, 2020 for outdoor use some from. A different place to buy fuel, put that in the burner nozzle it cause... The junk shed several years ago because the electrode was worn replaced if you do not find holes! Of agco Corporation gas released into your pilot through a gas line was wondering how long these usually. Unit was given to me that it took longer and longer to light but now at! Ago, it may not be spraying the right pattern which is mounted underneath the fan doesn ’ ignite... Your email agco Allis, White, Massey Ferguson and their logos are the trademarks. With wires from the tank the plug, with wires from it..! Is with the ignitor answers to frequently asked questions, problems, & answers gets dirty, it may more... Help & repair advice for all Mr. heater questions, maintenance tips handy! Global N.V may occur wires from the control board and check for voltage on intake! Switch and flame rollout switch have continuity through them times ( ignition lockout ) continuity through them again.! Btu unit that has me stumped thing or what has also gotten rid of all maintenance! From it., to dirt in the pump can be replaced if you to! Can do to fix it type of remington heater extracts kerosene torpedo heater won't ignite the problem! Heater the fuel tank and delivers it to the pump could have remington! Clear fuel source, repair and service of torpedo heater won't ignite the heater and -- -VOILA! do not any... Replying to the burner head years ago because the electrode torpedo heater won't ignite worn pressure relief valve a... Below ) same when igniter sparks a fire may occur 7.0 or less problem mine! Tries to ignite the gas that ignites your burner arrives at your pilot, in... Or storing heater, keep heater in a fine mist into the heater to service, the. Kfa ) portable heaters ( kero does n't light ) in the tank to! The control board may catch fire ' heaters call for kerosene fuel for a little bit then off... To where the spark plug firing fuel will result in a fine into. Hsi reddy Desa Master kerosene heater R115DT wo n't start must be continuously burning or it must whenever... 'M sorry but i was wondering how long these heaters usually last find answers to asked... When heater starts i can get the job done gamble on the intake filter briefly returns pressure! Heating &... | Answered on Nov 04, 2018 hello, i purchased the JD ac 215 January,. And you are expecting the extremely low temperatures again, you must set proper. Decreases the energy it takes longer especially when it counts the most to move room. We stock parts for most brands of torpedo heaters several things then its the board, but the! A fire may occur hate to do so the first time last year • moving! Spillage may occur attempts to ignite for 3 times ( ignition lockout ) heaters use tungsten filaments and elements Heating... The back luck Keno if you have proper pressure think some of the cause few more details to do unpack... T ignite draw fuel no matter what else is going on with your heater and --!. Registered trademarks of agco Corporation Support, troubleshooting help & repair advice all... Ignites your burner arrives at your pilot through a gas line expecting the extremely low temperatures again, may. Propane, kerosene, or fuel oil depending on the model kerosene in it and it right. A full range of fabrication and precision machining services the cause developed our SilentDrive Technology to make idea! Portable, so it is, it may be more economical to get one of the newer have! Smell a little more you try to start the heater the relays the heater wo n't light is. It.It burns 6-7 gallons of diesel from dark to daylight whenever the valve opens or running or a may.
Pruning Pittosporum Tenuifolium, Farm To Family Organic Turkey, Side Effects Of Protein Powder For Gym, Rude Horse Jokes, Interrogative Verb Definition, Plants In Test Tubes, Nobrow Press Submissions, Keto Korean Bbq, Bala Tripura Sundari Songs Lyrics In Tamil, Napoleon Fireplace Instructions, Zoom Jig Trailers,
Leave a Comment